Echosounder version 1.4 vs. 1.5

What is the difference between the echosounder versions 1.4 and 1.5?

Here is the new stuff in V1.5:

  • In BARCHECK mode Timegate is locked around the bar
  • In BARCHECK mode Blank result if depth falls outside the Timegate
  • Echo approval time is processed, depending on settings
  • BarCheck mode selected: = Approval/2
  • If Range = 5m and RX = 0 or 1: = Approval/2
  • Corrects an error in GT command.
  • Disable display channel 2 when operating NS200 in single mode
  • New default values
  • Initial lockout: Ch1 = 60cm, Ch2 = 120cm
  • Start NS215 and 415 in MUX mode
  • NS215 and 415 Recorder mode is 1/2
  • Force Communication to NMEA in a NS205
  • Use high paper speed when printing settings
  • Values and steps of Feet mode is changed
  • Revised the AUX function
  • Added, a Mark function to print Depth with AUX data
  • Added, a after stripping the AUX input
  • Rescheduled AUX repeater priority to be concurrent with Com port
  • Corrected a buffer overflow error in AUX input
  • Corrected an error that always recorded Channel 1 if TimeGate lines were activated
  • Retro Implement LED blinking in V1.5.2++ to make it compatible with the new gray display foils